Brand | Safewill |
Model | ES80A-A6 |
Weight | 20-30Kg |
Certificates | EPA, ISO14001, ISO9001, ISO45001 |
Particulate Matter | PM2.5, PM10, TSP |
Detecting Gas | O3, NO2, SO2, CO, VOC |
Meteorological Parameters | Temperature, Humidity, Atmospheric Pressure |
This Environmental monitoring systems adopts integrated equipment based on the principle of microsensor technology. That is to say, a device may have multiple sensors that monitor different parameters of environmental air pollutants. A major feature of microsensors is that it can immediately output digital or analog signals after monitoring pollutant parameters. This makes it possible for micro air monitoring stations to display visual data in a short period of time. This is different from the manual operation required for the production of environmental air data by large atmospheric monitoring stations. Although this method makes the data more reliable, the speed is obviously slower.
These data will be transmitted to cloud servers for storage through wired or wireless transmission methods 4G LTE 3G GPRS GSM, which is also the foundation for the system platform to have more functions. Due to the importance of data transmission, functions such as network disconnection and continuation have been applied to Environmental monitoring.
Contact Us for a Quote Today
For more details about our products, pricing, and shipping information, feel free to reach out. We look forward to providing you with the best service possible!
Basic Information | ||||
Product Name | OEM Air Quality Monitoring System | |||
Detection Method | Diffusion / Suction | |||
Data Transmission | RS485 Modbus/4G LTE Optional | |||
Preheat Time | 90 Seconds | |||
Temperature/ Humidity | -20℃~50 ℃/10%RH ~95%RH (No Condensation) | |||
Power Supply/Consumption | AC220V/50Hz/Optional Solar Power Supply/80W(MAX) | |||
Size | 620*440*160MM | |||
The Main Material | Cold Rolled Steel Plate | |||
Installation Method | Outdoor Column Installation | |||
Protection Class | IP53 |
The Standard Gas Configuration | ||||
Gas Type | Measuring Range | Resolution | Indication Error | T90 |
O3 | 500ppb | 1ppb | ≤±10%FS | 120S |
NO2 | 500ppb | 1ppb | ≤±10%FS | 120S |
SO2 | 500ppb | 1ppb | ≤±10%FS | 120S |
CO | 50ppm | 0.1ppm | ≤±10%FS | 120S |
Optional Gases | ||||
Gas Type | Measuring Range | Resolution | Indication Error | T90 |
TVOC | 10ppm | 0.01ppm | ≤±10%FS | 120S |
H2S | 20ppm | 0.1ppm | ≤±10%FS | 120S |
NH3 | 20ppm | 0.1ppm | ≤±10%FS | 120S |
Particulate Technical Parameters | ||||
Project | Technical Indicators | |||
Measuring Range | PM2.5/10/TSP:(0-2000) μg/m3 | |||
Sampling Cutter | Cyclone Physical Cutter | |||
Sampling Time | Adjustable, Default Five Minutes | |||
Resolution | 1ug/m3 | |||
Sampling Mode | Suction Type | |||
Air Intake Heating | Heating And Dehumidifying According To Air Humidity | |||
Malfunction Alarm | Real-Time Display Of Fault Alarms | |||
Zero Method | Automatic zero calibration | |||
Meteorological And Other Parameters(Optional) | ||||
Parameters | Range | Resolution | Accuracy | |
Temperature | -30℃--50℃ | 0.1℃ | ±1℃ | |
Humidity | 0-95%Rh | 1%Rh | ±5%Rh | |
Wind Speed | 0~60m/s | 0.1 m/s | ±1m/s | |
Wind Direction | 0-360° | 1° | / | |
Atmospheric Pressure | 600—1100hPa | 1 hPa | / | |
Noise | 30dB(A)~130dB(A) (A-weighted) | / | ±3dB | |
Rainfall | 0~4mm/min | 0.1mm | ±0.4mm (≤10mm) ±4%(>10mm) | |
Illumination | 0~200,000 Lux | / | ±7% (25℃) | |
UV Radiation | 0~400mW/㎡ | 1mW/㎡ | ±5% |